Model NO.: FGZ
Type: Continuous Vacuum
Name: Vacuum Dryer/ Vacuum Drying Machine
Material: Stainless Steel
Tem.: Low Tenmperature
Pressure: Negative Pressure
Pump: Water Ring Vacuum Pump
Heating Source: Hot Water or Steam
Temperature: 30-140
Structure: Oven
Operation Pressure: Vacuum Dryer
Application: API Powder/ Extract/ Tablet/ Granule/ Pill
Trademark: CK
Transport Package: Wooden Case
Specification: CE, SGS, ISO, GMP
Origin: Changzhou
HS Code: 8419399090
Vacuum Dryer/Pharmaceutical Vacuum Drying Machine for API Pharmaceutical

Application
:
It's suitable for drying heat sensitive material, it's widely used in pharmaceutical, chemical, food and electronic industries.
Vacuum Dryer/Pharmaceutical Vacuum Drying Machine for API Pharmaceutical
 

Features:

1.Under the condition of vacuum,the boiling point of raw material will decrease and make the evaporation efficiency increase. Therefore for a certain amount of heat transfer, the conducting area of dryer can be saved.
2. The heat source for evaporation may be low pressure steam or surplus heat steam.
3. The heat loss is less.
4.Before drying,the treatment of disinfection may be carried out during the period of drying,there is no impurity material mixed. It is in conformity.
5. It belongs to static dryer. So the shape of raw material to be dried should not be destroyed.
 
Questions before quotation:
1.       Material name
2.       Material initial moisture and final moisture\
3.       How many kg per batch or per day
4.       Heating source is steam or hot water?


Vacuum Dryer/Pharmaceutical Vacuum Drying Machine for API Pharmaceutical
 


Techinical specification:
Model Name YZG-600 YZG-800 YZG-1000 YZG-1400A FZG-10 FZG-15 FZG-20
Inter size of drying chamber(mm) Φ600×976 Φ800×1247 Φ1000×1527 Φ1400×2054 1500×1060 ×1220 1500×1400 ×1220 1500×1800 ×1220
Outer size of drying chamber(mm) 1135×810 ×1024 1700×1045 ×1335 1693×1190 ×150 2386×1675 ×1920 1513×1924 ×1720 1513×1924 ×2060 1513×1924 ×2500
Layers of baking support 4 4 6 8 5 8 12
Interval of baking(mm) 82 82 102 102 122 122 122
Size of baking tray(mm) 310×600 ×45 520×410 ×45 520×410 ×45 460×640 ×45 460×640 ×45 460×640 ×45 460×640 ×45
Quantity of baking tray 4 8 12 32 20 32 48
working pressure inside the pipe of baking support(Mpa) ≤0.784 ≤0.784 ≤0.784 ≤0.784 ≤0.784 ≤0.784 ≤0.784
Operation temperature of baking support, oC 35-150 35-150 35-150 35-150 35-150 35-150 35-150
Degree of vacuum inside the chamber when operation (Mpa) -0.09~0.096
Under the condition of -0.1Mpa and 110oC,evaporation rate of water(kg/m2.hr ) 7.2 7.2 7.2 7.2 7.2 7.2 7.2
When condenser is used,Model,and power of vacuum pump(kw) 2X-15A 2KW 2X-30A 3KW 2X-30A 3KW 2X-70A 5.5KW 2X-70A 5.5KW 2X-70A 5.5KW 2X-90A 2KW
When condenser is not used,Model,and power of vacuum pump(kw) SK-0.8 2.2KW SK-2.7 4KW SK-3 5.5KW SK-6 11KW SK-3 5.5KW SK-6 11KW SK-6 11KW
Weight of drying chamber(kg ) 250 600 800 1400 1400 2100 3200
 
 

Shantui SL50W loader Brake System troubleshooting methods for five common faults
The loader has played a vital role in today's engineering construction. A good grasp of the characteristics of the loader's braking system and simple troubleshooting methods can ensure the normal use of the loader. Below, the editor will share with you the troubleshooting methods of five common faults of the loader brake system, I hope it will be helpful to everyone!
1. Run off after braking
The direct cause of deviation is caused by the unequal braking torque of the wheels on both sides. Common causes of failure:
(A) The Brake Caliper disc has serious oil pollution, and the friction system is seriously reduced, resulting in an imbalance of braking torque. At this time, the oil on the brake caliper disc should be removed;
(B) The sub-Cylinder piston is stuck and cannot work. Step on the brake of the stationary car, observe the working condition of the sub-cylinder, and dismantle and inspect as necessary.
2. The pressure of the barometer rises slowly
Main reason:
(A) Air leakage in the pipeline;
(B) The air pump is not working properly;
(C) The one-way valve is corroded and stuck;
(D) The drain bolt of the oil-water separator is not tightly closed or the pressure regulator valve is leaking.
Troubleshooting method: First, remove the air leakage in the pipeline, and then check the working status of the air pump. Remove the air pump outlet pipe and press the air outlet with your thumb. If the exhaust pressure is low, the air pump is malfunctioning. If the air pump is in good working condition, check the oil-water separator oil drain plug or pressure regulating valve to avoid bypass, and troubleshoot through inspection. Finally, check the two one-way valves in the three-way joint. The blockage of the one-way valve will cause the air reservoir to fail or slow down. In this way, the brake system failure of the loader can be solved.
3. Insufficient braking force, weak
Main reason:
(A) The brake leaks;
(B) There is air in the brake oil circuit;
(C) The wheel hub oil seal is broken, and there is grease on the clamp plate;
(D) The brake is severely worn and the friction surface is burned;
(E) Air pressure adjustment is too low.
The above-mentioned loader brake system failures can be eliminated by repairing, adjusting or replacing parts according to their respective causes.
4. When stepping on the brake, oil mist sprays out
(A) The brake light switch is damaged, and high pressure oil is sprayed from the switch interface. Replace the switch to solve it.
(B) The length of the piston rod of the afterburner pump is too large. This situation may occur when the afterburner pump assembly is newly replaced. The cause of the brake system failure of this loader is: the piston rod is adjusted too long, causing the piston stroke to be too large when the afterburner pump is working, and the brake fluid is drained The hole flows back into the afterburner pump and ejects.
During installation, the working stroke of the piston should be measured to determine the length of the piston rod.
5. Brake issuance
Fault phenomenon: The loader is struggling to walk and touch the clamp plate with hand after parking, the clamp plate becomes hot. main reason:
(A) The friction plate wears thin, the dust ring is damaged and water enters, and the piston is corroded and stuck;
(B) The return spring in the afterburner pump is weak or broken, and the high-pressure oil cannot be added.


SEM 50F, 650 Brake System
Liugong loaders ZL50CN, 855N, 856 Brake System,
SDLG 956L 952H 953 Brake System,
XCMG Brake System LW500KL ZL50GN,
Komatsu WA380, WA380-3, WA380-5, WA430-5 Brake System
DEGONG loader Brake System
Foton Lovol Loader Brake System
Lonking 855N loader Brake System
XGMA 932 936 956 Loader Brake System
Changlin Loader Brake System
Shantui SL50W Brake System
And we have more.

Brake System