Special features of the valve - balance valve Knowledge Introduction: First, the concept and superior performance: â–² Balance Valve: is a special function of the valve, it has a good flow regulating characteristics, the relative flow and the relative opening of a linear relationship. Accurate valve opening instructions, the minimum reading of the valve full opening of 1%. Reliable opening lock memory device, the valve opening changes can be restored to the original lock position. There are cut-off functions, the installation of the balance valve eliminates the need to install a stop valve. A quantitative measurement and adjustment functions, the system debugging, commissioning personnel and special intelligent instrumentation man-machine dialogue, the balance valve to adjust, you can achieve system hydraulic balance. Second, the application of occasions: 1, boilers or chillers: Boiler or chiller installed in parallel, if the flow of each unit and its rated flow inconsistent, the unit will not be efficient point of operation, affecting the unit to maximize efficiency. In this case, balance valves should be installed at each boiler or chiller so that each unit can achieve the designed output to ensure the safe and normal operation of each unit. Chiller connected to multiple cooling towers, each cooling tower should also be installed balance valve. 2, district heating pipe network: residential heating pipe network often by a boiler room or heat station to several buildings heating. The main pipe, main pipe and the main pipe connected to the entrance of the building pipe composition. Because each building is located at a distance from the heat source, the lack of effective equipment to eliminate the residual head pressure in the near-loop will cause the flow distribution to fall short of design requirements, resulting in overheating of the proximal end and overheating of the distal end. The balance valve should be installed on each main pipe and each branch pipe to ensure the flow balance between the main pipe and each building. 3, building heating and air conditioning pipe network: building heating and air conditioning pipe network system, to meet the energy requirements, we need to ensure that all of the riser and branch pipe are in line with the design flow. At this time, balance valves should be installed on the manifold, mains, risers and manifolds. 4, the thermal station: In the thermal power station or boiler room to a number of heating stations for hot water system, in order to get the required thermal power station water flow should be installed on each loop side of the heat balance valve station. In order to ensure that the secondary loop water flow is the design flow, the balance valve should also be installed on each secondary loop side of the thermal station. More Keyword Search: Balance Valve

carbon steel casting WCB, WCC, WC5, WC6, LCC, LCB, LC3, C12A, stainless steel casting CF8, CF8M, CF3, CF3M, gate valve casting, globe valve casting, swing Check Valve casting, raw casting of gate valve, raw casting of Butterfly Valve, raw casting of globe valve, cast steel casting of gate valve, cast steel raw cating of butterfly valve, China leading foundry for cast steel gate valve, globe valve, swing check valve, ball valve, butterfly valve, and plug valve. Sand mould steel casting, lost wax casting of gate valve, investment casting of ball valve, precision steel casting of gate valve

Forging and Casting

Cast Steel Vs Forged Steel,Cast Iron Vs Forged Steel,Forged Or Cast,Forged Steel Forging Mill Ball Components

SUZHOU RSF VALVE CO.,LTD , https://www.rsf-valve.com